Electric · Storage System
10 Year Tank
1 Years Parts and Labour
10 Year Tank
1 Year Parts and Labour
5 Year Tank
1 Year Parts and Labour
Thermann Technical Support
Free sizing service available
Multiple element configurations available
Great for areas where gas is not available
No flue or exhaust emissions
Limited capacity
Requires more space
Plug in options not available
Thermann Technical Support
Free sizing service available
Multiple element configurations available
Great for areas where gas is not available
No flue or exhaust emissions
Limited capacity
Requires more space
Plug in options not available
Always use a licensed plumber when installing a hot water system.
Electric · Storage System
The Thermann Commercial 315L electric storage tanks are low maintenance and offer high performance and fast recovery via multiple elements heating water at the same time. They are perfect for heavy demand commercial and industrial applications. They are a great alternative where reticulated gas is not available, or fluing arrangements are impractical. The Thermann Commercial Electric storage range offers a 5 year commercial tank warranty and 1 year parts and labour. - Adjustable water temperature from 65°C to 80°C (for sanitising); 70°C ex-factory
1. A hot water tap is turned on
2. Hot water is drawn from the top of the
tank
3. Cold water enters through the bottom of the
tank
4. When temp around the element drops, elements
activate
5. Hot water rises to the top of the tank
6. Tank is refilled with cold water and the
process repeats
SPECIFICATIONS | 315THMC336 | 315THMC348 | 315THMC360 | 315THMC636 | 315THMC648 | 315THMC660 |
---|---|---|---|---|---|---|
Storage Capacity(L) | 321 | 321 | 321 | 321 | 321 | 321 |
Hot Water Delivery(L) | 315 | 315 | 315 | 315 | 315 | 315 |
Net Weight Empty(kg) | 93 | 93 | 93 | 94 | 94 | 94 |
Element(s) Sizes(kW) | 3 x 3.6 | 3 x 4.8 | 3 x 6.0 | 6 x 3.6 | 6 x 4.8 | 6 x 6.0 |
Cable Entry Size(mmL) | 25 | 25 | 25 | 32 | 32 | 32 |
Electrical Connection(3 phase) | 415V AC | 415V AC | 415V AC | 415V AC | 415V AC | 415V AC |
Water Connections Female | 32mm(1 1/4") | 32mm(1 1/4") | 32mm(1 1/4") | 32mm(1 1/4") | 32mm(1 1/4") | 32mm(1 1/4") |
Relief Valve Pressure(kPa) | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 |
Max. Inlet Pressure(kPa) | 800 | 800 | 800 | 800 | 800 | 800 |
Max. Thermostat Setting | 80°C | 80°C | 80°C | 80°C | 80°C | 80°C |
Number of Elements | 3 | 3 | 3 | 6 | 6 | 6 |